Wire Mesh Tomography System for Horizontal Two-phase Fluid Flow Investigation

Authors

  • Leong Lei Yeng School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Ruzairi Abdul Rahim School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Navintiran Rajan School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Mohd Shukri Manaf School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Mohd. Hafiz Fazalul Rahiman Faculty of Electrical Engineering Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis
  • Anita Ahmad School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Yusri Md. Yunus School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Sallehudin Ibrahim School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai
  • Yasmin Abdul Wahab Faculty of Electrical & Electronic Engineering, Universiti Malaysia Pahang, Pekan Campus, 26600 Pekan, Pahang
  • Mimi Faisyalini Ramli Faculty of Technology Engineering, Universiti Tun Hussein Onn, Campus Pagoh.
  • Suzanna Ridzuan Aw Abdullah Faculty of Electrical & Automation Engineering Technology, Terengganu Advanced Institute Technical College (TATIUC), Telok Kalong, 24400 Kemaman, Terengganu

Abstract

Simultaneous flow of liquid and gas is commonly found in process industries, such as petroleum pipeline transport, chemical process, oil and gas pipeline transport and many more. Phase distribution monitoring and visualizing for such flow is important to ensure the operation safeness and effectiveness. This study aims to investigate wire-mesh tomography system on solid-free two-phase flow monitoring and visualization. Experiment was conducted on a horizontal liquid/gas flow with an inner diameter of 84mm. A 16 x 16 wire-mesh sensor was designed and applied in this study to obtained the raw data from the target flow. The sensor worked together with transceiver circuit and data acquisition and image reconstruction software to visualize the flow condition and void fraction. Tomogram images were resulted as the final results of this experiment.

Downloads

Published

2021-10-15

How to Cite

Yeng, L. L. ., Abdul Rahim , R. ., Rajan , N., Manaf , M. S. ., Fazalul Rahiman, M. H. ., Ahmad , A. ., … Aw Abdullah , S. R. . (2021). Wire Mesh Tomography System for Horizontal Two-phase Fluid Flow Investigation. ELEKTRIKA- Journal of Electrical Engineering, 20(2-3), 42–48. Retrieved from https://elektrika.utm.my/index.php/ELEKTRIKA_Journal/article/view/324